Benchtop Multiparameter Analyzer F-BMA102
Home Testing Meter Multiparameter Analyzer Benchtop Multiparameter Analyzer F-BMA102
Benchtop Multiparameter Analyzer F-BMA102
Benchtop Multiparameter Analyzer F-BMA102 is a touch screen multifunction device that has the operational function of 11 parameters which are measured from an aqueous solution. It has a pH range of -2.000 to 20.000 pH and a conductivity range of 0.000 μS/cm to 199.9 mS/cm. The results are provided accurately on the LCD screen and it has a storage capacity of 200 sets with over 20 settable parameters. The results are all precise due to its automatic function features such as auto diagnosis of electrodes, auto buffer, and sample recognition with temperature compensation.
| pH Range | -2.000 to 20.000 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | -2000.00 to 2000.00 mV |
| mV Resolution | 0.01 mv |
| mV Accuracy | ±0.03 % FS |
| Ion pX Range | 0.000 to 14.000 pX |
| Ion pX Resolution | 0.001 pX |
| Ion pX Accuracy | ±0.002 pX |
| Ion concentration Range | 0 to 19990 Unit: mol/L, mmol/L, g/L, mg/L, μg/L |
| Ion concentration Resolution | 4-digit Significant Number |
| Ion concentration Accuracy | ±0.5 % |
| Conductivity Range | 0.000 μS/cm to 199.9 mS/cm |
| Conductivity Resolution | 0.001 μS/cm |
| Conductivity Accuracy | ±0.5 % FS |
| Resistivity Range | 5.00 Ω.cm to 20.00 MΩ.cm |
| Resistivity Resolution | 0.01 Ω.cm |
| Resistivity Accuracy | ±0.5 % FS |
| TDS Range | 0.000 mg/L to 19.99 g/L |
| TDS Resolution | 0.001 mg/L |
| TDS Accuracy | ±0.5 % FS |
| Salinity Range | 0.00 to 8.00 % |
| Salinity Resolution | 0.0001 |
| Salinity Accuracy | ±0.1 % |
| DO Range | 0.00 to 19.99 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.10 mg/L |
| DO concentration Range | 0.0 to 199.9 % |
| DO concentration Resolution | 0.001 |
| DO concentration Accuracy | ±2.0 % |
| DO saturation Range | - |
| DO saturation Resolution | - |
| DO saturation Accuracy | - |
| Temperature Range | -5.0 to 135.0 ℃ |
| Temperature Resolution | 0.1 ℃ |
| Temperature Accuracy | ±0.3 ℃ |
| Power Supply | 100 V to 240 V (50/60Hz) |
| Dimension | 280×215×93 mm |
| Weight | 1 kg |
5 inches touch screen LCD display screen with backlight for clear visible results |
Automatic/Manual temperature compensation is delivered that ensures accurate results |
It is comprised of over 20 settable parameters that have a number of calibration points, stability criteria, and temperature unit |
It has an Auto-hold feature that senses and locks the measurement endpoint |
Multiple reading feature is present that allows the reader to auto-read, timed-read and continuous-read |
It is delivered with a data capacity of up to 200 sets |
Data can be transferred to PC or printer through USB or RS-232 communication |
pH |
It is comprised of automatic electrode diagnosis that has pH slope and offset display |
Auto-buffer recognition for various samples and has 1 to 5 points calibration |
Ion concentration |
Direct reading mode, Standard addition mode, sample addition mode, and GRAN mode are in-built along with Multi measurement method |
User-defined method is maintained and it has over 10 methods are in-built that includes F-, Cl-, Br-, I-, NO3-, BF4-, NH4+, K+, Na+, Ca2+, Cu2+, Pb2+, Ag+ and so on |
The measurement unit can be Selected, that are ?g/L, mg/L, g/L, mmol/L, PX, etc 1-5 points calibration is processed |
Conductivity |
Settable parameters are present that include cell constant, reference temperature, temperature compensation coefficient, and TDS factor |
Auto sample recognition for various samples and has 1 to 3 points calibration |
DO |
Auto sample recognition for various samples and has 1 to 2 points calibration |
Manually barometer pressure compensation can be done according to preferring results |
This multi-parameter analyzer can be used in processes such as wastewater treatment, drinking water supply and is necessary to support life and treatment developments. In addition, the meter can be used in research institutions, and at a variety water quality related production sites in the mining, agriculture, forestry and fishery industries, for measuring the ionic concentration and various laboratories for the researches, drug manufacture processes, agriculture to measure the salinity levels of surface water and of soil samples, environmental protection, cosmetic industry food processing etc.